Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A, offers motor protection, ATEX, and emergency stop up to SIL 3. Possible group shut-down, supply, and relay extension via DIN rail connector., ELR H3-IES-PT- 24DC/500AC-3-P
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector., ELR H5-I-PT- 24DC/500AC-9-P
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 9 A and offers motor protection. Possible supply and relay extension via DIN rail connector., ELR H3-I-PT- 24DC/500AC-9-P
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector., ELR H5-I-PT- 24DC/500AC-3-P
Hybrid motor starter as an alternative to a conventional contactor circuit. Starts 3~ AC motors up to 3 A and offers motor protection. Possible supply and relay extension via DIN rail connector., ELR H3-I-PT- 24DC/500AC-3-P
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 9 A, offers motor protection and emergency stop up to SIL 3/PL e. Possible group shut-down, supply, and relay extension via DIN rail connector., ELR H5-IS-PT- 24DC/500AC-9-P
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 9 A, offers motor protection and emergency stop up to SIL 3/PL e. Possible group shut-down, supply, and relay extension via DIN rail connector., ELR H3-IS-PT- 24DC/500AC-9-P
Hybrid motor starter as an alternative to a conventional reversing contactor. Reverses 3~ AC motors up to 3 A, offers motor protection and emergency stop up to SIL 3/PL e. Possible group shut-down, supply, and relay extension via DIN rail connector., ELR H5-IS-PT- 24DC/500AC-3-P
Hybrid motor starter as an alternative to a conventional protective circuit. Starts 3~ AC motors up to 3 A, offers motor protection and emergency stop up to SIL 3/PL e. Possible group shut-down, supply, and relay extension via DIN rail connector., ELR H3-IS-PT- 24DC/500AC-3-P
Relay extension module for ELR-...-P hybrid motor starters, feedback of forward and reverse running when control signal is present, Push-in connection, DIN rail connector included, EM-2RPT/21AU-R/L-P
Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 1.3 A, QUINT4-PS/1AC/24DC/1.3/PT
Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 2.5 A, QUINT4-PS/1AC/24DC/2.5/PT
Primary-switched power supply unit, QUINT POWER, Push-in connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.8 A, QUINT4-PS/1AC/24DC/3.8/PT
Plug-in lightning current arrester, in accordance with Type 1/Class I, for 3-phase power supply networks, with separate N and PE (L1, L2, L3, PE, N)., FLT-SEC-P-T1-3S-264/50-FM
Pluggable surge protective device free of leakage current, in accordance with Type 2/Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact., VAL-SEC-T2-3S-350VF-FM
Pluggable surge protective device free of leakage current, in accordance with Type 2/Class II, for 3-phase power supply networks with combined PE and N installed in one conductor (4-conductor system: L1, L2, L3, PEN), with remote indication contact., VAL-SEC-T2-3C-350VF-FM
Pluggable surge protective device free of leakage current, in accordance with Type 2/Class II, for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), with remote indication contact., VAL-SEC-T2-1S-350VF-FM
Replacement plug free of leakage current for surge protective devices from the VALVETRAB SEC product range for L-N and L-PEN paths., VAL-SEC-T2-350VF-P
Customer-specific VARIOFACE module for traffic technology (traffic light systems). Contacting of disconnect terminal blocks via varistor circuit and status indicators on FLK connector., P-VAR95-048B KEN-I PHD
DIN rail housing, Lower housing part with metal foot catch, tall design, with vents, width: 35.2 mm, cross connection: without bus connector, number of positions cross connector: not relevant, color: black (9005), ME 35 UT BK
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB pin strip (1x 37-position); cable length: 1 m, CAB-DSUB37M/OE/22/S/ 1M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB pin strip (1x 37-position); cable length: 3 m, CAB-DSUB37M/OE/22/S/ 3M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB pin strip (1x 37-position); cable length: 5 m, CAB-DSUB37M/OE/22/S/ 5M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB pin strip (1x 37-position); cable length: 10 m, CAB-DSUB37M/OE/22/S/10M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB pin strip (1x 37-position); cable length: 15 m, CAB-DSUB37M/OE/22/S/15M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB pin strip (1x 37-position); cable length: 30 m, CAB-DSUB37M/OE/22/S/30M
Universal plug-in surge arrester base for up to 240 V applications with two conductors plus ground, with remote indication contact, VAL-MS BE/1+1/1U/FM
Universal varistor-based plug-in lightning/surge arrester for 48 V DC applications with grounded return conductor (positive pole), without risk assessment for Lightning Protection Levels III and IV, with remote indication contact., VAL-MS-T1/T2 48/12.5/1+1/1U/FM
Universal varistor-based plug-in surge arrester for 48 - 60 V DC applications with two conductors plus ground, with remote indication contact, VAL-US 60/1+1/1U/FM
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB socket strip (1x 37-position); cable length: 10 m, CAB-DSUB37F/RA/OE/22/S/10M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB socket strip (1x 37-position); cable length: 15 m, CAB-DSUB37F/RA/OE/22/S/15M
Assembled shielded round cable; connection 1: Single wires (37-position) (The wires are marked and fitted with ferrules.); connection 2: D-SUB socket strip (1x 37-position); cable length: 30 m, CAB-DSUB37F/RA/OE/22/S/30M
Pluggable surge protective device, in accordance with Type 2/Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact. With 40 kA discharge capacity in accordance with the requirements of VDE 0100-534:2016-10 relating to SPDs at the system feed point., VAL-SEC-T2-3S-350/40-FM
Pluggable surge protective device, in accordance with Type 2/Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE). With 40 kA discharge capacity in accordance with the requirements of VDE 0100-534:2016-10 relating to SPDs at the system feed point., VAL-SEC-T2-3S-350/40