With six product lines, Phoenix Contact offers an innovative portfolio of industrial electro-technology: Best connections from the sensor to the
controller. From the classical modular terminal block to splash-proof machine connectors to the wireless Ethernet, Phoenix Contact provides innovations
which do more than our customers expect.
To get price for your interested product, please enter product code:
All prices are considered EXW RIGA, LATVIA w/o VAT, You can calculate shipping costs, when you add products in your cart. Exact product availability will be checked before Proforma Invoice is sent
2-channel Ex i output signal conditioner, HART. Isolates and transmits 0/4…20 mA signals with intrinsic safety to a load in the Ex area. Galvanic 4-way electrical isolation, line fault detection, SIL 2 (SC3) in accordance with IEC 61508, Push-in connection., MACX MCR-EX-IDS-2I-2I-SP
32-channel output relay module (one N/O contact) with a screw connection and a fuse (1 A). The voltage supply and 50-pos. system connector are designed redundantly. Suitable for Yokogawa ADV551 card., UM-2KS50/32R/F/J/ADV551
32-channel input relay module (one N/O contact) with a screw connection and a fuse (1 A). The voltage supply and 50-pos. system connector are designed redundantly. Suitable for Yokogawa ADV151 card., UM-2KS50/32R/F/J/ADV151
Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, automatic start, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS20-1NO-1DO-24DC-SC
Safety relay for emergency stop and safety doors up to SILCL 1, Cat. 1, PL c, depending on the application up to SILCL 3, Cat. 4, PL e, 1-channel operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS25-1NO-1DO-24DC-SC
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS30-1NO-24DC-SC
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, cross-circuit detection, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS35-1NO-24DC-SC
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic start, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS40-1NO-1DO-24DC-SC
Safety relay for emergency stop and safety doors up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS45-1NO-1DO-24DC-SC
Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, non-equivalent operation, automatic start, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS50-1NO-1DO-24DC-SC
Safety relay for monitoring non-equivalent signal generators up to SILCL 3, Cat. 4, PL e, 2-channel, non-equivalent operation, manual, monitored start, 1 enabling current path, US = 24 V DC, fixed screw terminal block, PSR-MS55-1NO-1DO-24DC-SC
Safety relay for emergency stop, safety doors, and light grids up to SILCL 3, Cat. 4, PL e, 1 or 2-channel operation, automatic start, 2 enabling current paths (1-channel), US = 24 V DC, fixed screw terminal block, PSR-MS60-2NO-24DC-SC
Dummy module with no function for connecting unused intrinsically safe signal cables, with plug-in screw connection terminal blocks., MACX MCR-EX-DUMMY-ISOLATOR
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 1.0 m, FLK 50-PA/EZ-DR/HF/KS/ 100/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 2.0 m, FLK 50-PA/EZ-DR/HF/KS/ 200/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 3.0 m, FLK 50-PA/EZ-DR/HF/KS/ 300/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 4.0 m, FLK 50-PA/EZ-DR/HF/KS/ 400/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 5.0 m, FLK 50-PA/EZ-DR/HF/KS/ 500/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 6.0 m, FLK 50-PA/EZ-DR/HF/KS/ 600/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 7.0 m, FLK 50-PA/EZ-DR/HF/KS/ 700/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 8.0 m, FLK 50-PA/EZ-DR/HF/KS/ 800/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 9.0 m, FLK 50-PA/EZ-DR/HF/KS/ 900/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 10.0 m, FLK 50-PA/EZ-DR/HF/KS/1000/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 15.0 m, FLK 50-PA/EZ-DR/HF/KS/1500/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 20.0 m, FLK 50-PA/EZ-DR/HF/KS/2000/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 25.0 m, FLK 50-PA/EZ-DR/HF/KS/2500/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 30.0 m, FLK 50-PA/EZ-DR/HF/KS/3000/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 35.0 m, FLK 50-PA/EZ-DR/HF/KS/3500/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 45.0 m, FLK 50-PA/EZ-DR/HF/KS/4500/YOC
Cast front adapter with attached, halogen-free round cable and a 50-pos. socket strip injection-molded on both sides for the connection of Yokogawa ProSafe controllers. Cable length: 50.0 m, FLK 50-PA/EZ-DR/HF/KS/5000/YOC
16-channel analog input module with screw connection, redundant voltage supply, and additional jumpers for each channel. Suitable for Yokogawa SAI 143 card., UM-2KS40/16AI-J/SI/RS/SO225
Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (selective fuse breaking) technology, input: 12 V DC, output: 12 V DC/8 A, QUINT-PS/12DC/12DC/8
Primary-switched QUINT DC/DC converter for DIN rail mounting with SFB (selective fuse breaking) technology, input: 48 V DC, output: 48 V DC/5 A, QUINT-PS/48DC/48DC/5
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (Selective Fuse Breaking) technology, input: 60-72 V DC, output 24 V DC / 10 A, QUINT-PS/60-72DC/24DC/10
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (selective fuse breaking) technology, input: 96 - 110 V DC, output: 24 V DC/10 A, QUINT-PS/96-110DC/24DC/10
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (Selective Fuse Breaking) technology, input: 60-72 V DC, output 24 V DC / 10 A, QUINT-PS/60-72DC/24DC/10/CO
Primary-switched QUINT DC/DC converter with wide range input for DIN rail mounting with SFB (selective fuse breaking) technology, input: 96 - 110 V DC, output: 24 V DC/10 A, QUINT-PS/96-110DC/24DC/10/CO
Partition plate for NS-35/7,5 DIN rails to ensure a clearance of 50 mm between the controller and surge protection for PT-IQ-EX systems., PT-IQ-EX-L-PP
Partition plate for NS-35/7,5 isolated DIN rails (DIN rail is isolated using the AB/NS support bracket) to ensure a clearance of 50 mm between the controller and surge protection for PT-IQ-EX systems., PT-IQ-EX-H-PP
Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Screw connection technology, standard configuration., MINI MCR-2-UNI-UI-2UI
Universally configurable 4-way signal duplicator, with plug-in connection technology for the electrical isolation and duplication of analog signals. Configurable via DIP switch or software. Push-in connection technology, standard configuration., MINI MCR-2-UNI-UI-2UI-PT
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 24 V DC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks, ST-OV2- 24DC/ 60DC/1
Lightning and surge arrester combination, in accordance with Type 1+2/Class I+II, for 3-phase power supply networks, with separate N and PE (L1, L2, L3, PE, N). Consisting of 3x FLT 35 CTRL-4.0 and 3x VAL-MS 400/FM and 1x FLT 100N/PE-1.5, incl. bridges and marking., POWERSET BC-385/3+1-100/FM
Plug-in power solid-state relay, with LED and protective circuit in input and output circuits, input: 110 V DC, output: 12 - 60 V DC/max. 1 A, can be plugged into basic terminal blocks, ST-OV2-110DC/ 60DC/1
16-channel module for Honeywell C300 analog output cards with disconnect, test points, socketed 500 mA fuses and fuse status indicator., UM-D37M/DS/FU/LED/AO/C300/R