With six product lines, Phoenix Contact offers an innovative portfolio of industrial electro-technology: Best connections from the sensor to the
controller. From the classical modular terminal block to splash-proof machine connectors to the wireless Ethernet, Phoenix Contact provides innovations
which do more than our customers expect.
To get price for your interested product, please enter product code:
All prices are considered EXW RIGA, LATVIA w/o VAT, You can calculate shipping costs, when you add products in your cart. Exact product availability will be checked before Proforma Invoice is sent
Runtime license for Visu+ including redundancy, networking, and alarm statistics functions where the I/O data and variables in scripting are limited to 1024 bytes., VISU+ 2 RT 1024 RED NET AS
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3)., ILC 131 ETH
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3)., ILC 151 ETH
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3)., ILC 171 ETH 2TX
The Inline controller offers the option of communicating via PROFINET and Modbus/TCP. Programming is carried out using PC Worx Express or PC Worx (IEC 61131-3)., ILC 191 ETH 2TX
Inline Controller with Ethernet interface and GSM modem for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with plug and labeling field., ILC 151 GSM/GPRS
Axio control for direct open-loop control of Axioline I/Os. With 2 Ethernet interfaces and programming capabilities according to IEC 61131-3. Complete with connector connector and labeling field., AXC 1050
Axiocontrol for the direct control of Axioline F I/Os. With 3 Ethernet interfaces for the additional connection of distributed I/Os via PROFINET, Modbus TCP or TCP/IP. Programming according to IEC 61131-3. Includes connector plug and marking field., AXC 3050
Runtime license for Visu+ including 3 web clients and alarm dispatcher function where the I/O data and variables in scripting are limited to 1024 bytes. 2 direct driver connections are also supported., VISU+ 2 RT-D 1024 WEB3 AD
Safety-related digital input module, IP20 protection, for the SafetyBridge V3 and PROFIsafe system. The module has 8 safe digital inputs for two-channel assignment or 16 safe digital inputs for single-channel assignment., IB IL 24 PSDI 16-PAC
Inline analog input terminal, complete with accessories (connector and marking field), 8 channels, TC (thermocouple), RTD (resistance temperature detector), 2 and 3-conductor connection technology, IB IL TEMP 8 UTH/RTD-PAC
Inline, Digital output terminal, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-wire, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field, IB IL 24 DO 4/EF-PAC
Inline communication terminal, for serial data transmission, complete with accessories (connector connector and labeling field), 1 serial input and output channel in RS-485/422 or RS-232 design, transmission speed 2 Mbaud, IB IL RS UNI-2MBD-PAC
Runtime license for Visu+ including 3 web clients and networking function where the I/O data and variables in scripting are not limited., VISU+ 2 RT UNLIMITED NET WEB3
Inline controller for use under harsh ambient conditions, with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with connector and labeling field., ILC 131 ETH/XC
I/O extension module for use with Nanoline base unit. Equipped with 2 analog input (0...10 V DC, -10...+10 V DC, 0/4...20 mA) and 2 analog output (0...10 V DC, 0/4...20 mA) channels. A maximum of three I/O extension modules can be attached to a base unit., NLC-IO-2AI-2AO-01
24 V DC Nanoline base unit. Equipped with 6 digital input and 4 relay output channels. Additional I/O channels can be added using a maximum of three I/O extension modules. Optional communication modules provide network or serial connectivity. Optional Operator Panel provides user interface. Programming is via nanoNavigator., NLC-050-024D-06I-04QRD-05A
24 V AC/DC Nanoline base unit. Equipped with 8 digital input and 4 relay output channels. Additional I/O channels can be added using a maximum of three I/O extension modules. Optional communication modules provide network or serial connectivity. Optional Operator Panel provides user interface. Programming is via nanoNavigator., NLC-050-024X-08I-04QRX-05A
I/O extension module for use with Nanoline base unit. Equipped with 6 digital input and 4 PNP digital output channels. A maximum of three I/O extension modules can be attached to a base unit., NLC-IO-06I-04QTP-01A
I/O extension module for use with Nanoline base unit. Equipped with 6 digital input and 4 NPN digital output channels. A maximum of three I/O extension modules can be attached to a base unit., NLC-IO-06I-04QTN-01A
Runtime license for Visu+ including alarm statistics function where the I/O data and variables in scripting are not limited. 2 direct driver connections are also supported., VISU+ 2 RT-D UNLIMITED AS
Runtime license for Visu+ including alarm dispatcher function where the I/O data and variables in scripting are limited to 256 bytes. 2 direct driver connections are also supported., VISU+ 2 RT-D 256 AD
I/O extension module for use with Nanoline base unit. Equipped with 4 analog input channels. A maximum of three I/O extension modules can be attached to a base unit., NLC-IO-4AI
Set for mounting devices with EPA design to wall or mast, including mast clips for a diameter of 25 - 85 mm, can be moved on two axes for optimum alignment, stainless steel, FL EPA WMS
Inline controller for use under harsh ambient conditions, with Ethernet interface for coupling to other controllers and systems, with programming options according to IEC 61131-3, complete with connector and labeling field., ILC 151 ETH/XC
Runtime license for Visu+ including networking function where the I/O data and variables in scripting are limited to 2048 bytes., VISU+ 2 RT 2048 NETWORKING
Runtime license for Visu+ including 3 web clients where the I/O data and variables in scripting are limited to 128 bytes. 2 direct driver connections are also supported., VISU+ 2 RT-D 128 WEB3 AD
Inline XC, Bus coupler, INTERBUS, Inline shield connector, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields, IBS IL 24 BK-T/U-XC-PAC
INTERBUS branch terminal, version for extreme conditions, complete with accessories (connector plug and labeling field), with remote bus branch, 24 V DC, IBS IL 24 RB-T-XC-PAC
Inline XC, Digital input terminal, Digital inputs: 4, 24 V DC, connection method: 3-wire, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field, IB IL 24 DI 4-XC-PAC
Inline XC, Digital output terminal, Digital outputs: 4, 24 V DC, 500 mA, connection method: 3-wire, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field, IB IL 24 DO 4-XC-PAC
Inline XC, Analog input terminal, Analog inputs: 2, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 500 kbps, Extreme conditions version, degree of protection: IP20, including Inline connector and labeling field, IB IL AI 2/SF-XC-PAC
Inline function terminal, version for extreme conditions, for connecting a CAN bus system, complete with accessories (connector and labeling field), IB IL CAN-MA-XC-PAC
Inline power terminal, version for extreme conditions, complete with accessories (connector and labeling field), 24 V DC, without fuse, IB IL 24 PWR IN-XC-PAC
Inline segment terminal, version for extreme conditions, complete with accessories (connector and labeling field), 24 V DC, with fuse, IB IL 24 SEG/F-XC-PAC
Runtime license for Visu+ including 1 web client where the I/O data and variables in scripting are limited to 64 bytes. 2 direct driver connections are also supported., VISU+ 2 RT-D 64 WEB1